Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17 44
3 Configuring the I/O system in the »Engineer«
3.3 Setting the communication path and going online
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4. Click the Search/Enter... button to check the bus connection selected from the Bus
connection list field.
•The Select device access path dialog box is shown:
5. Select the corresponding device from the Field devices located list field.
6. Press OK.
•The Select device access path dialog box is closed.
•In the Communication path dialog box, the Device access path column displays the
corresponding device access path (e.g. "can:/dev1/").
7. In the Communication path dialog box, click the Connect button to establish an online
connection to the I/O system.
In the Project view, a yellow icon indicates the online connection to the I/O system 1000:
The and icons provide an easy possibility to first establish and then disconnect an online
connection to the I/O system 1000.
When an online connection has been established, the »Engineer« displays the current parameter
settings of the I/O system 1000 with a yellow background colour.
Stop!
If you change parameters in the »Engineer« while an online connection to the device is
established, the changes are directly accepted in the device!