Address Name / seng range / [default seng] Informaon
0x2C02:001
(P351.01)
Motor parameter (ASM): Rotor resistance
(ASM mot
or par.: Rotor resistance)
0.0000 ... [8.8944]* ... 200.0000 Ω
* Default seng dependent on the model.
Equivalent circuit data required for the motor model of the
asynchronous machine.
0x2C02:002
(P351.02)
Motor parameter (ASM): Mutual inductance
(ASM motor par.: Mutual induct.)
0.0 ... [381.9]* ... 50000.0 mH
* Default seng dependent on the model.
0x2C02:003
(P351.03)
Motor parameter (ASM): Magnesing current
(ASM mot
or par.: Magn. current)
0.00 ... [0.96]* ... 500.00 A
* Default seng dependent on the model.
0x2C03:005 D-axis inductance Ld
0.000 ... [23.566]* ... 500.000
mH
* Default seng dependent on the model.
From version 05.03
0x2C03:006 Q-axis inductance Lq
0.000 ... [23.566]* ... 500.000 mH
* Default seng dependent on the model.
From version 05.03
Conguring the motor control
Opons for opmizing the control loops
Mot
or equivalent circuit diagram data
182