In the following, all parameters relevant for the sequence conguraon are given.
If the sequencer is
acve, write accessed to all parameters are blocked that
concern the acve sequence conguraon!
Parameter
Address Name / seng range / [default seng] Informaon
0x4030:001 ...
0x4030:016
(P830.01 ... 16)
Sequence 1: Step 1 ... Step 16
(Sequence 1: St
ep 1 ... Step 16)
Conguraon of the steps 1 ... 16 for sequence 1.
Alternavely to calling a single segment, a complete sequence (with a
higher number) can also be called from one step. This, for instance,
serves to congure a main sequence from which several
subsequences are called successively.
With the seng "0", the respecve step is skipped.
-8 Sequence 8
-7 Sequence 7
-6 Sequence 6
-5 Sequence 5
-4 Sequence 4
-3 Sequence 3
-2 Sequence 2
0 Skip step
1 Segment 1
2 Segment 2
3 Segment 3
4 Segment 4
5 Segment 5
6 Segment 6
7 Segment 7
8 Segment 8
0x4031
(P831.00)
Number of cycles sequence 1
(Cy
cl. sequence 1)
1 ... [1] ... 65535
From version 03.00
Denion of how oen the sequence 1 is to be passed through.
1 = one pass, 2 = two passes, ...
65535 = innite number of cycles.
0x4032:001 ...
0x4032:016
(P835.01 ... 16)
Sequence 2: Step 1 ... Step 16
(Sequence 2: Step 1 ... Step 16)
Conguraon of the steps 1 ... 16 for sequence 2.
Alternavely to calling a single segment, a complete sequence (with a
higher number) can also be called from one step. This, for instance,
serves to congure a main sequence from which several
subsequences are called successively.
With the seng "0", the respecve step is skipped.
-8 Sequence 8
-7 Sequence 7
-6 Sequence 6
-5 Sequence 5
-4 Sequence 4
-3 Sequence 3
0 Skip step
1 Segment 1
2 Segment 2
3 Segment 3
4 Segment 4
5 Segment 5
6 Segment 6
7 Segment 7
8 Segment 8
0x4033
(P836.00)
Number of cycles sequence 2
(Cy
cl. sequence 2)
1 ... [1] ... 65535
From version 03.00
Denion of how oen the sequence 2 is to be passed through.
1 = one pass, 2 = two passes, ...
65535 = innite number of cycles.