EasyManua.ls Logo

Lenze i410 - Page 88

Lenze i410
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Name / seng range / [default seng] Informaon
0x403A:001 ...
0x403A:016
(P855.01 ... 16)
Sequence 6: Step 1 ... Step 16
(Sequence 6: St
ep 1 ... Step 16)
Conguraon of the steps 1 ... 16 for sequence 6.
Alternavely to calling a single segment, a complete sequence (with a
higher number) can also be called from one step. This, for instance,
serves to congure a main sequence from which several
subsequences are called successively.
With the seng "0", the respecve step is skipped.
-8 Sequence 8
-7 Sequence 7
0 Skip step
1 Segment 1
2 Segment 2
3 Segment 3
4 Segment 4
5 Segment 5
6 Segment 6
7 Segment 7
8 Segment 8
0x403B
(P856.00)
Number of cycles sequence 6
(Cycl. sequence 6)
1 ... [1] ... 65535
From version 03.00
Denion of how oen the sequence 6 is to be passed through.
1 = one pass, 2 = two passes, ...
65535 = innite number of cycles.
0x403C:001 ...
0x403C:016
(P860.01 ... 16)
Sequence 7: Step 1 ... Step 16
(Sequence 7: Step 1 ... Step 16)
Conguraon of the steps 1 ... 16 for sequence 7.
Alternavely to calling a single segment, a complete sequence (with a
higher number) can also be called from one step. This, for instance,
serves to congure a main sequence from which several
subsequences are called successively.
With the seng "0", the respecve step is skipped.
-8 Sequence 8
0 Skip step
1 Segment 1
2 Segment 2
3 Segment 3
4 Segment 4
5 Segment 5
6 Segment 6
7 Segment 7
8 Segment 8
0x403D
(P861.00)
Number of cycles sequence 7
(Cy
cl. sequence 7)
1 ... [1] ... 65535
From version 03.00
Denion of how oen the sequence 7 is to be passed through.
1 = one pass, 2 = two passes, ...
65535 = innite number of cycles.
0x403E:001 ...
0x403E:016
(P865.01 ... 16)
Sequence 8: Step 1 ... Step 16
(Sequence 8: Step 1 ... Step 16)
Conguraon of the steps 1 ... 16 for sequence 8.
With the seng "0", the respecve step is skipped.
0 Skip step
1 Segment 1
2 Segment 2
3 Segment 3
4 Segment 4
5 Segment 5
6 Segment 6
7 Segment 7
8 Segment 8
0x403F
(P866.00)
Number of cycles sequence 8
(Cy
cl. sequence 8)
1 ... [1] ... 65535
From version 03.00
Denion of how oen the sequence 8 is to be passed through.
65535 = innite number of cycles.
Conguring the frequency control
Congure setpoint sources
Sequencer
88

Table of Contents

Other manuals for Lenze i410

Related product manuals