Starting/turning off the engine for driving
4.2 Turning off the engine
Operating manual GMK 6400 3 112 993 en 4 - 25
12.07.2013
4.2 Turning off the engine
4.2.1 On the ignition lock/with hand-held control/on the outrigger
control units
If the temperature of the coolant is very high, let the engine run for another
one or two minutes at increased idling speed.
If the hand-held control is not connected:
• Turn the ignition key to position 0 – the engine will stop.
If the hand-held control is connected:
• Press the button (1) – the engine goes off.
In this case it is not possible to switch off the engine with the ignition lock.
On the outrigger control units, if the hand-held control is not connected:
• Press the button (1) – the engine goes off.
After parking If you want to park the truck crane;
à p. 5 - 53.
G
Risk of accidents due to the fact that the truck crane cannot be steered.
Only turn off the engine once the truck crane is at a standstill. If you remove
the ignition key, the steering will lock and you will lose control of the mov-
ing truck crane.