Malfunctions during crane operation
14.4 Troubleshooting
Operating manual GMK 6400 3 112 993 en 14 - 21
12.07.2013
14.4.11 Malfunctions on the outriggers
Malfunction Cause Solution
Outrigger cylinders and
beams can neither be
extended nor retracted and
the inclination indicator does
not work
Driver's cab: Fuses A3F3,
A3F13, A3F14 blown.
Replace blown fuse;
à p. 7 - 20.
When operating with the
hand-held control
Driver's cab: Fuse A2F3 blown Replace blown fuse;
à p. 7 - 20
When operating from the
crane cab
Hand-held control connected
to the superstructure or a
bridging plug not inserted
Disconnect hand-held control
or insert bridging plug;
à p. 12 - 22
When operating from the con-
trol units
Display fields switched off. Switch on display fields;
à p. 12 - 33
Hand-held control connected
to the superstructure or a
bridging plug not inserted
Disconnect hand-held control
or insert bridging plug;
à p. 12 - 22
None of the specified causes
apply
Solenoid valves not working Manitowoc Crane Care must
be notified