Rigging work
12.4 Connecting/disconnecting the hand-held control
12 - 22 3 112 993 en Operating manual GMK 6400
12.07.2013
Connecting the hand-held control
• Open the cap (2) and pull the bridging plug
(3) out of the socket (1)
• Insert the plug (4) into the socket (1) and
secure it with the cap (2)
• After about 20 seconds, the lamps (5) and (6)
light up – the ignition is switched on
There is a malfunction if the lamp (5) does not
light up or flash;
à p. 14 - 20.
Disconnecting the hand-held control
• Open the cap (2)
• Pull the plug (4) out of the socket (1) – the
lamps (5) and (6) go out
• Insert the bridging plug (3) into the socket
(1) and secure it with the cap (2)
The ignition is turned off, unless it is switched
on at an ignition lock.
G
Danger due to unauthorised use
Always stow the hand-held control in the driver's cab or in the crane cab
before you leave the crane, and lock the doors.
That way you can prevent unauthorised persons from starting the engine.