EasyManua.ls Logo

Manitowoc GROVE GMK 6400

Manitowoc GROVE GMK 6400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Starting/turning off the engine – for crane operation
10.1 When starting the engine for the first time of the day
Operating manual GMK 6400 3 112 993 en 10 - 9
12.07.2013
With flame start
system
The flame start system warms the suction air of the engine.
This section pertains to starting a warm and cold engine.
The flame start system is activated each time the ignition is turned on:
When the engine is warm, the lamp (1) will only light up briefly (2 to 3 sec-
onds).
When the engine is cold, the lamp (1) goes out as soon as the engine has
been preheated (up to 20 seconds).
Start the engine within the next 30 seconds; otherwise, you must switch
on the ignition again and wait until the lamp goes out.
H
If the lamp (1) does not go out, there is a fault in the flame start system; refer
to Manitowoc Crane Care.
Wait until the lamp (1) goes out.
Do not press the accelerator.
Turn the ignition key to position 2 and hold it there until the engine starts.
Let go of the ignition key after the engine starts.
If the engine does not start, release the ignition key after about 15 seconds
and wait one minute before trying again.
H
If the engine does not start after multiple attempts; à Malfunctions on the
engine
, p. 14 - 12.
S
Danger of explosion when using starter fuel
The engine may never be started with the aid of starter fuel. The starter fuel
sprayed into the suction unit can ignite.

Table of Contents

Related product manuals