Crane operation
11.2 Operation of the rated capacity limiter
11 - 42 3 112 993 en Operating manual GMK 6400
12.07.2013
The lamps of the status display light up or flash depending on the RCL
degree of utilisation and operation of the switches.
Switch pressed
Degree of utilisation
0 - 90% approx.
90 - 100%
greater than
100%
No switch
(normal operation)
Display (4)
green
Display (5)
yellow
Display (6)
red
Key-operated
rigging switch (1)
Display (4)
green
Display (5)
yellow
Display (5)
yellow,
flashing
Button (2)
Raise the boom
Display (4)
green
Display (5)
yellow
Display (4)
green, flashing
Key-operated
override switch (3)
Display (6) red,
flashing
Display (6) red,
flashing
Display (6) red,
flashing

Table of Contents