Malfunctions during crane operation
14.4 Troubleshooting
Operating manual GMK 6400 3 112 993 en 14 - 35
12.07.2013
• Check the fuses (1) and replace them if nec-
essary.
Antenna plugs
• Check whether the plugs (1) and (2) are
plugged in:
s
Designation Amperage
F3401 5 A
F3402 5 A
1 Plugs for GSM/GPS antenna
2 Plug for satellite antenna