Malfunctions during crane operation
14.5 Emergency operations and programmes
14 - 54 3 112 993 en Operating manual GMK 6400
12.07.2013
Applying values
Press the left dead man's switch (2).
Also press button (5) once – symbol (3)
appears.
Press the buttons (1) in the following order:
Å
Æ
Å
Ç
The symbols (4) confirm the entry.
If your input was incorrect, all symbols (5) go
out and you need to re-enter.
If the target values entered are not permissi-
ble, the values on the display (2) turn red.
If the target values entered are permissible,
the values on the display (2) turn green.
The display
(1) shows the symbol for the cur-
rent status.
S
Risk of damage due to incorrect input
Before working with the crane, check whether ECOS indicates the current
telescoping and correct if this is not the case.
Entering incorrect values causes malfunctions and may result in damage to
the telescoping mechanism.