EasyManua.ls Logo

Manitowoc GROVE GMK 6400

Manitowoc GROVE GMK 6400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Malfunctions during crane operation
14.6 Hydraulic emergency operation
14 - 66 3 112 993 en Operating manual GMK 6400
12.07.2013
Derricking Determine the maximum permissible working radius for the current rig-
ging mode according to
Lifting capacity table
Lowering the boom
Observe the maximum permissible working
radius specified in the
Lifting capacity table
if necessary by using a measuring tape to
check.
Move the control lever (2) towards B.
Raising the boom
Move the control lever (1) towards B.
Lifting/lowering
Move the control lever (1) in the required
direction:
G
Danger of overturning if the working radius is too large when lowering the
boom
In emergency operation, operations are not shut down by the RCL. This
also applies if the RCL displays are still active after switching on the igni-
tion. The truck crane will overturn if you exceed the maximum permissible
working radius for the current rigging mode as specified in the
Lifting capac-
ity table
.
A: Lowering
B: Lifting

Table of Contents

Related product manuals