– Programming Manual 13. Programming 89
Gap control trigger modality
The Gap output control is triggered when the noise level exceeds limit
S1.
The Gap output control is triggered when the noise level drops below
limit S1.
Data programming: press to highlight the involved field, press or to view
the desired condition, then to confirm.
Gap control self-locking
The Gap control can be either self-locked or not.
Self-locked control. Once supplied, the Gap output control is reset only
after the successive start cycle.
NON self-locked control. The Gap output control is reset when the noise
level drops below the S1 trigger limit.
Data programming: press to highlight the involved field, then press to define
the status of the data.
F Value of the filter on the GAP background noise
Filter programmable on the GAP background noise to prevent the GAP control from
triggering after unexpected noise variations or oscillations not due to the contact
between wheel and workpiece. The programmed value represents the response time
of the filter to an unexpected noise variation.
Setting range for F: 0 to 0.060 seconds (resolution 0.001 seconds).
Default value: F = 0.000 seconds.
Value programming: press to highlight the involved field, press or to
view the desired value, then to confirm.
noise
noise