EasyManua.ls Logo

MIMAKI CFL-605RT - Setting Register Mark Sensor Height

MIMAKI CFL-605RT
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-11
1
1
1
4
Register Mark Reading Functions
Detecting Register Marks
Setting height of register mark
Reading the register mark and set the height of the sensor.
1
Move the mark sensor on top of the register mark
with the jog key.
2
Loosen the thumbscrew.
3
Lower the lever to a height that the gauge shaft
contacts the register mark.
4
Tighten the screw while the height guage shaft is
in contact with the register mark and release the
hand from the lever.
Until tighten the screws, hold it lowered the lever.
After cutting the data with mark sensor, lift up the mark sensor. When set a felt mat while lowering the
mark sensor, the set guide plate may be hit by the head and may cause the head damage.
Make sure that the height gauge shaft is in
contact with the register mark.
Use always lever for vertical movement of
the mark sensor. If do with the
thumbscrew, it will not be in the correct
height.
Make sure that the lever is raised.
Firmly fix thumbscrew.
Register mark
Mark sensor
Thumbscrew
Lever

Table of Contents