95
Measurement
5
5.4. Measurement in sequential mode
(3) Operation of automatic free fall compensation
:KHQ\RXPDNHDPHDVXUHPHQWLQVHTXHQWLDOPRGHZLWKDXWRPDWLFIUHHIDOOFRPSHQVDWLRQVHWWR
[VALID], the average value of the actual free falls that occurred in the latest four measurements
DUHDXWRPDWLFDOO\FDOFXODWHGDVFRUUHFWLRQYDOXHVWKDWDUHUHÀHFWHGRQZHLJKLQJYDOXHV
POINT
,IZHLJKLQJYDOXHVHWWLQJYDOXHRI>),1$/@H[FHHGVWKHVHWWLQJYDOXHRI>$))
COMPENSATION], automatic free fall compensation is not executed.
- If [A. F. F. COMPENSATION] of [BRAND CODE] has been set to 0, automatic
free fall compensation is not executed.
(YHQLI\RXWXUQRII&6'%DXWRPDWLFIUHHIDOOFRPSHQVDWLRQYDOXHVZLOOEH
retained.
5.4.5. Use of safety check input
<RXFDQHQWHUWKHVHWWLQJVVRWKDWPHDVXUHPHQWDXWRPDWLFDOO\VWRSVZKHQDIDLOXUHRFFXUV
IRUH[DPSOHWKHZHLJKLQJKRSSHUIDOOVGRZQRUDFRQWDLQHUWR¿OOWKHGLVFKDUJHGPHDVXUHG
object fails to be prepared.
7RXVHVDIHW\FKHFNLQSXWDIWHUHQWHULQJWKHQRUPDOVHWWLQJVRI>6(48(17,$/02'(@
ĺ6HWWLQJVEHIRUHPHDVXUHPHQWVHWWKHIROORZLQJLWHPV
>,2,1387@WR>,2,1387@DOORFDWLRQRIVDIHW\FKHFNLQSXWWRH[WHUQDOFRQWUROLQSXWV
- [BATCHING SAFETY CHECK]
- [DISCH. SAFETY CHECK]
- [RECIPE SAFETY CHECK]
- [MIXING SAFETY CHECK]
6DIHW\FKHFNFRQGLWLRQIRUJHQHUDOVHTXHQFH
(1) Allocation of safety check input to external control inputs
7RXVHVDIHW\FKHFNLQSXWDOORFDWHVDIHW\FKHFNLQSXWWRH[WHUQDOFRQWUROLQSXWVVXFKDVD
VDIHW\FKHFNVZLWFKDQGDVDIHW\FKHFNVHQVRU$OORFDWHWKHVDIHW\FKHFNLQSXWIXQFWLRQWRWKH
FRUUHVSRQGLQJ,2LQSXWRIWKHH[WHUQDOFRQWUROLQSXWV<RXFDQDOORFDWHXSWRHLJKWVDIHW\
FKHFNLQSXWV
1) Display [I/O] screen
1. Tap [I/O] on [MENU 1/2].
>,26(77,1*@ZLOOEHGLVSOD\HG
2) Allocate the safety check input function to the I/O input
1. Tap [I/O INPUT1] on [I/O SETTING 2/6].
$OLVWRIIXQFWLRQVWKDWFDQEHDOORFDWHGWR>,2
,1387@ZLOOEHGLVSOD\HG