145
Kaleido-X
User’s Manual
5In External Alarm Providers Configuration, review the alarm providers list, and then
add or remove devices, as required.
• To add a device to the providers list, select the device from the Host address list, or
type the appropriate IP address in the box, and then click Add.
• To remove a device from the alarm providers list, select it, and then click Remove.
6 Once you have added all devices required for your purposes, click OK to close the
window.
7On the File menu, click Save.
Managing Virtual Alarms
Creating Virtual Alarms
To create a virtual alarm
1 Connect XEdit to the multiviewer (see Using XEdit Online, on page 67).
2On the Tools menu, click New virtual alarm.
Alternatively, after clicking the Actions tab, or while a text or alarm level is selected in
the sources table you can:
•Right-click Virtual alarms in the filtered System list, point to Virtual alarm, and
then click New.
Note: To qualify as an external alarm provider, an iControl application
server must have its lookup service enabled.
See External Alarm Provider on
page 135.