368
Tally Interface Devices
Zodiak Production Switcher
Text level selection for the text label in a UMD
8 Click outside the composite to lock it, if applicable.
9Repeat step 4step 8 until you have configured all UMDs that are to display dynamic
text and tally status when this layout is loaded on the monitor wall.
10 On the File menu, click Save.
11 If you are working in offline mode, then you must export the database to your
multiviewer: on the Configure menu, point to Database, and then click Export.
On the monitor wall, you can now load the layout containing the monitors that were
assigned dynamic text and tallies provided by the Kayenne switcher. Input or output
names, as well as tally status from the Kayenne switcher will be visible on the monitor wall.
Any changes made by the switchers operator will be immediately reflected on the monitor
wall.
Zodiak Production Switcher
A multiviewer can receive dynamic source names and tally information from a Grass Valley
Zodiak Digital Production Switcher. The procedures below describe how to set up a
multiviewer to interface with this family of production switchers.
Configuring the Zodiak Switcher
To establish a serial connection between the switcher and your multiviewer, you need to
identify the serial port you wish to use for tally contribution in the switchers Engineering
Setups, by using the Zodiak touch screen menu panel or the Zodiak Menu application. You
also need to configure or take note of the communications settings and use the same
values on the multiviewers side. The procedure below is an example using the default
values typically used on Grass Valley production switchers.
To set up the Zodiak switcher
1 Physically connect one end of an RJ-45 straight cable to the multiviewers RS-422 port.