EasyManua.ls Logo

Miranda Kaleido-X16 - Calibrating Zero VU Reference Level for an Embedded Audio Source

Miranda Kaleido-X16
461 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
114
Calibrating the Kaleido-X
Detailed Directions
Detailed Directions
Multiviewer Output Calibrations
Calibrating the Brightness and Contrast
Each of the output heads in the multiviewer can drive a monitor wall display. For each head,
output parameters can be adjusted to optimize the image on the monitor wall display: the
brightness parameters set the black offsets of the RGB output signals; and the contrast
parameters set the gain offsets of these signals.
To calibrate the brightness and contrast parameters
1 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar.
A hierarchical list representing the current system appears.
2 In the list, expand the multiviewer whose output heads you wish to calibrate.
3 Expand the appropriate output module.
The expanded module will show the output heads. (Depending on the multiviewer
model, other items may also appear.)
GPI/Genlock Calibrations
GPI line direction On Kaleido-X systems with a GPI/genlock module, GPI lines can be
configured as inputs or outputs. On the Kaleido-X16 and KMV-
3901/3911 multiviewer models, the GPI lines are unidirectional (4 out
and 32 in for the Kaleido-X16, 2 out and 8 in for the KMV-3901/3911). In
all cases, the state of any GPI output can be set manually for test
purposes, by using their ON/OFF calibration.
See GPI/Genlock
Calibrations on page 132.
Note: The KMV-3901/3911 multiviewers do not support brightness and
contrast calibrations.

Table of Contents

Other manuals for Miranda Kaleido-X16