The following data is deleted:
The system and terminal configuration data of the terminals on the interfaces that
are no longer present in the new configuration.
The system configuration data of the network interfaces that are no longer present
in the new configuration.
Tab. 85 Example: Reducing the number of terminal or network interfaces
Note:
If the terminal configuration data of system terminals is deleted following the reconfiguration of
a card, a warning message will appear beforehand to give you the possibility of cancelling the
process. However, this is possible only if the configuration data of the original card was not
already deleted beforehand.
6. 3. 3. 3 New card with more ports
A card is replaced by a similar card with more ports.
Procedure:
1. Change the card and put the system into operation again. Similar procedure as de-
scribed in "
Replacing a defective interface card", page 191.
2. In the WebAdmin view Cards and modules ( =4g) Confirm the new cards.
3. Configure new ports.
The system configuration data (User No., User configuration, etc.) of the terminals on
the new ports is created as new data (default values).
Tab. 86 Example: Expanding the number of terminal or network interfaces
6. 3. 3. 4 Change slot
Interface cards can be moved to a different slot. The terminal configuration data of the
system phones can be transferred.
Procedure:
1. Change the slot and put the system into operation again. Similar procedure as de-
scribed in "
Replacing a defective interface card", page 191.
TIC-4TS
TIC-2TS The configuration data of terminal interfaces 3 and 4 are deleted.
TIC-4AB
TIC-2AB The configuration data of network interfaces 3 and 4 are deleted.
TIC-2TS
TIC-4TS The configuration data of terminal interfaces 3 and 4 are created as new.
TIC-2AB
TIC-4AB The configuration data of network interfaces 3 and 4 are created as new.