Annex
247
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
Analogue network interfaces
Voice path with A/D and D/A conversion (standard PCM, A-law)
Transmission as per ES 201 168 (level country-specific)
Signalling as per TBR 21
Pulse or DTMF dialling, Flash signal
Loop current detection
Call charge receive 12 or 16 kHz (frequency and level setting country-specific)
CLIP detection in accordance with ETS 300 778-1
7. 4. 2 Terminal interfaces
The following technical data applies to the terminal interfaces:
Digital terminal interface DSI
Proprietary interface, two-wire
Two system phones of the MiVoice 5300 series can be connected per interface
(AD2 protocol)
1)
One SB-4+/SB-8 radio unit can be connected (with 8 channels the SB-8 radio units
requires two DSI interfaces)
Power supply min. 75 mA, limiting at approx. 80 mA, terminal voltage 36…48 V
Line termination in the phone
Transparent transmission of 2 PCM channels
Digital terminal interface BRI-S
Standard Euro ISDN interface
Phantom power supply min. 140 mA, limiting at approx. 170 mA, terminal voltage
36…41 V
Up to 8 terminals can be connected
Maximum of 2 simultaneous call connections
Analogue terminal interface FXS
Configurable multifunctional interface for connecting analogue terminals and equip-
ment.
The following applies for the FXS mode Phone / Fax, two-wire door and general
bell:
1) Office 10, Office 25, Office 35, Office 45/45pro are supported as before