Operation and Maintenance
224
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
Software upgrade IP system
phone successful
The software update of an MiVoice 5361 IP /
5370 IP / 5380 IP has now been successfully
completed after unsuccessful attempt(s).
User number, termi-
nal ID, date, time
critical
(positive,
with
match)
Software upload During an upload in system status:
Update running
Supervision running
Normal operation
Parameter 1:
0: "New communi-
cation server soft-
ware loaded, start-
ing...",
•1: New communi-
cation server soft-
ware crashed, roll-
back performed
3: New communi-
cation server soft-
ware started and
running well
Date, time
Normal
(without
match)
Standard SIP terminals within
the licence limit again
SIP Terminals and Video Terminals licences are
now available.
Parameter 1=1: SIP
Term ina ls licence,
Parameter 2=1:
Video Terminals
licence, date, time
Serious
(positive,
with
match)
Synchronisation loss on trunk A BRI/PRI interface entered in the clock pool
has lost the system clock
Port number, date,
time
Serious
(negative,
with
match)
Synchronisation re-estab-
lished
Synchronization with the network has been
restored on at least one BRI/PRI interface.
Date, time
Serious
(positive,
with
match)
Synchronisation with backup
communication server failed
The primary communication server was unable
to transmit the configuration data to the backup
communication server.
Note:
This event message is generated by the primary
communication server.
Backup communica-
tion server ID, date,
time
critical
(negative,
with
match)
Synchronisation with backup
communication server suc-
cessful
The primary communication server was able
(following one or more previous failed attempts)
to transmit the configuration data to the backup
communication server.
Note:
This event message is generated by the primary
communication server.
Backup communica-
tion server ID, date,
time
critical
(positive,
with
match)
Synchronization on trunk re-
established
A BRI/PRI interface entered in the clock pool
has been successfully re-synchronized with the
system clock.
Port number, date,
time
Serious
(positive,
with
match)
Event message Trigger condition Details