INVERTER SETTINGS
39
3
Pr. 340
Setting
Pr. 79
Setting
Operation Mode at Power-On or Power
Recovery
Operation Mode Switchover
0
(default)
0
(default)
External operation mode
Switching among external, PU, and NET operation modes is
enabled
*1
1
PU operation mode
PU operation mode fixed
2 External operation mode
Switching between external and NET operation modes is
enabled, switching to PU operation mode is disallowed
3, 4
External/PU combined operation mode
Operation mode switching is disallowed
6 External operation mode
Switching among external, PU, and NET operation modes is
enabled while running.
7
X12 (MRS) signal ON.....external operation mode
Switching among external, PU, and NET operation modes is
enabled
*1
X12 (MRS) signal OFF...external operation mode
External operation mode fixed (forcibly switched to external
operation mode.)
1, 2
*2
0
NET operation mode
Same as when Pr. 340 = "0"
1
PU operation mode
2
NET operation mode
3, 4
External/PU combined operation mode
6
NET operation mode
7
X12 (MRS) signal ON....NET operation mode
X12 (MRS) signal OFF...external operation mode
10, 12
*2
0 NET operation mode
Switching between PU and NET operation modes is
enabled
*3
1
PU operation mode
Same as when Pr. 340 = "0"
2
NET operation mode
NET operation mode fixed
3, 4
External/PU combined operation mode
Same as when Pr. 340 = "0"
6 NET operation mode
Switching between PU and NET operation modes is
enabled while running
*3
7
External operation mode
Same as when Pr. 340 = "0"
*1
The operation mode cannot be directly changed between PU mode and NET mode.