FX3U Series Programmable Controllers
User's Manual - Hardware Edition
85
5 Version Information and Peripheral Equipment Connectability
5.4 Cautions on using transparent port (2-port) function of GOT-F900 Series
1
Introduction
2
Features and
Part Names
3
Product
Introduction
4
Specifications
5
Version and
Peripheral
Devices
6
System
Configuration
7
Input/Output
Nos., Unit Nos.
8
Installation
9
Preparation and
Power Supply
Wiring
10
Input Wiring
5.4 Cautions on using transparent port (2-port) function of GOT-F900
Series
When monitoring circuits, device registration, etc. in an FX3U PLC from GX Developer Ver. 8.18U or later
using the transparent (2-port) function in the GOT-F900 Series, make sure to execute the following setting.
If the following setting is not provided, write to PLC, read from PLC, verify with PLC, etc. operate normally, but
monitoring (ladder monitor, entry datemonitor, etc.) cannot be normally executed.
Setting in GX Developer (Ver. 8.18U or later)
1 Select [Online] → [Transfer setup...] to open the "Transfer Setup" dialog box.
2 Double-click [PLC module] in [PLC side I/F] to open the [PLC side I/F Detailed
setting of PLC module] dialog box.
3 Put a check mark to the check box [via GOT-F900 transparent mode] as
shown below.
4 Click the [OK] button to finish the setting.
GX Developer
Ver. 8.12N or earlier
GX Developer
Ver. 8.18U or later
GX Developer Ver. 8.22Y or later
When directly
connecting GX
Developer to PLC
Set "COM port" and "Transmission speed" on "PC
side I/F Serial setting" dialog box.
Select "RS-232C" on "PC side I/F Serial
setting" dialog box, and set "COM port" and
"Transmission speed."
When using
transparent function in
GOT-F900 Series
Setting shown below is
required.
Setting shown below is
not required.
Select "RS-232C" on "PC side I/F Serial
setting" dialog box, and execute setting
shown below.
Double-click it.
Put a check mark to the
check box "via GOT-F900
transparent mode."

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U-4HSX-ADP and is the answer not in the manual?

Mitsubishi FX3U-4HSX-ADP Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U-4HSX-ADP
CategoryController
LanguageEnglish

Related product manuals