UNIVERGE SV8100 Issue 4.1
System Hardware Manual 3 - 75
4. Secure the battery compartment to the chassis using the two
screws provided and attach the battery cable to the 9.5”
chassis.
5. Reconnect AC power cable to rear of chassis.
6. To power on the 9.5” chassis, refer to Chapter 4, 2.6 Powering
Up the SV8100 on page 4-9.
3.3.3 CHSGW SMALL BATT BOX Fuse Replacement
1. Correct the issue which caused the fuse problem.
. Replacing fuses without first correcting the issue could cause a fire and/
or electric shock hazard.
2. Disconnect AC power cable from rear of chassis.
. Make sure to unplug the unit from the electrical outlet prior to removing
the connection cables within the battery box unit.
Figure 3-99 Attach to the CHS2U GW Chassis and
Connect Battery Cable
Only replace fuses of the same rating.
Fuses may be hot, use caution when replacing
them