2 - 20 SV8100 System Specifications
VA @ 230V: Base chassis=276VA, Expansion chassis=276VA, total
1104VA
KWh @ AC Input I x 230V/1000: Base chassis=0.276 KWh,
Expansion chassis=0.276 KWh, total 1.104 KWh
BTU (KWh x 3413): Base chassis=
942 BTU, Expansion chassis=942
BTU
, total 3768 BTU (at 240Vac)
A dedicated outlet, separately fused and grounded for each chassis
should be installed
5.2.2 Power Supply Consumption
5.3 Environmental Conditions
5.3.1 Temperature and Humidity
Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature: -20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades –
PZ-BS10, PZ-BS11, PZ-VM21, PZ-ME50, CD-8DLCA,
CD-16DLCA, PZ-8DLCB
Operating Temperature: 0
o
C ~ 40
o
C
Recommended Long Term Temperature: -20°C ~ 60°C
Humidity: 10 ~ 90% RH (non-condensing)
Table 2-17 Power Consumption
Chassis
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic Chassis – CD-CP00 Chassis 2.19 A 96 130
Basic Chassis + Expansion Chassis 4.38 A 192 260
Basic Chassis + 2 Expansion Chassis 6.57 A 288 390
Basic Chassis + 3 Expansion Chassis
8.76 A
384 520
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N