System Hardware Manual 2 - 19
5.2 Power Requirements
A dedicated 100VAC/120VAC/220VAC/230-240VAC 50HZ/60HZ circuit located
within seven feet of the chassis is required. A separate dedicated outlet for
each chassis should be installed.
5.2.1 Power Supply Specifications
AC240V Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 230 VAC @ 15A Controlling/Base Chassis
Power Consumption: Base Chassis=263VA, Expansion
Chassis=263VA, total 1060VA
Input Voltage: 90VAC to 264VAC
(Rated Voltage: 100VAC/120VAC/220VAC/230-240VAC)
Frequency: 47Hz - 63Hz (Rated frequency: 50/60Hz)
Phase and Wire: Single Phase, 2 Line + PE Type
Grounding Requirements: No. 14 AWG copper wire
Feeding Voltage: D
term
/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 230 VAC and with full load conditions:
. Base chassis can refer to either 9.5” or 19” chassis
Output Power: Base chassis=130W, Expansion chassis=130W, total
520W
AC Input I: Base chassis=1.15A, Expansion chassis=1.15A, total 4.6A
Table 2-16 Cabling Requirements
Connected Equipment Cable
Music on Hold and Background Music Sources Hi-Fi Shielded Audio Cable
External Amplifier Hi-Fi Shielded Audio Cable
ITL Cabling Cat 5 Straight Data Network
Cable – 328.1 ft (100m)
maximum distance.
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N side).