Issue 4.1 UNIVERGE SV8100
4 - 46 Installing the SV8100 Blades
Table 4-19 CD-8DLCA/CD-16DLCA Maximum Upgrade Capacities
provides the maximum capacities for the ESIU blades when they are
upgraded.
4.1.2 Installation
The CD-8DLCA/CD-16DLCA blades can be installed in any universal
slot in the system and up to a maximum of 20 DLCA blades can be
installed per system, providing up to 368 digital ports.
To install the PZ-8DLCB/CD-16DLCA:
1. If installing the CD-8DLCA and the PZ-8DLCB daughter board
is to be attached, do so now. Refer to 4.2.2 Installation on page
4-50.
2. Each CNx01 connector (CN101, CN201, CN301, CN401) is
used to connect up to four digital extensions.
4.1.3 LED Indications
LEDs for the CD-8DLCA
/CD-16DLCA are described in Table 4-20
CD-8DLCA/CD-16DLCA LED Indications. Each LED is listed with its
associated function and LED and Operational status. Refer to Figure
4-16 CD-8DLCA Blade and Figure 4-17 CD-16DLCA Blade for the
location of the LEDs on the blades.
Table 4-19 CD-8DLCA/CD-16DLCA Maximum Upgrade Capacities
ESIU
19”
Chassis
with CPU
19” Chassis
without CPU
19” Chassis
x4
Networked
Chassis
CD-8DLCA
5 6 23 32
CD-16DLCA
5 5 20 32
Table 4-20 CD-8DLCA/CD-16DLCA LED Indications
LED Indication
Operation Status Remarks
Live LED
(Green)
Busy LED
(Red)
On On System Initializing
Flash (1s) On The assignment of the unit is refused.
When you exceed the system
capacity.
When the main software
version is not matched.
Flash (1s) Trouble found during self-diagnostics.