Issue 4.1 UNIVERGE SV8100
4 - 46 Installing the SV8100 Blades
Table 4-19 CD-8DLCA/CD-16DLCA Maximum Upgrade Capacities
provides the maximum capacities for the ESIU blades when they are
upgraded.
4.1.2 Installation
The CD-8DLCA/CD-16DLCA blades can be installed in any universal
slot in the system and up to a maximum of 20 DLCA blades can be
installed per system, providing up to 368 digital ports.
To install the PZ-8DLCB/CD-16DLCA:
1. If installing the CD-8DLCA and the PZ-8DLCB daughter board
is to be attached, do so now. Refer to 4.2.2 Installation on page
4-50.
2. Each CNx01 connector (CN101, CN201, CN301, CN401) is
used to connect up to four digital extensions.
4.1.3 LED Indications
LEDs for the CD-8DLCA
/CD-16DLCA are described in Table 4-20
CD-8DLCA/CD-16DLCA LED Indications. Each LED is listed with its
associated function and LED and Operational status. Refer to Figure
4-16 CD-8DLCA Blade and Figure 4-17 CD-16DLCA Blade for the
location of the LEDs on the blades.
Table 4-19 CD-8DLCA/CD-16DLCA Maximum Upgrade Capacities
ESIU
19”
Chassis
with CPU
19” Chassis
without CPU
19” Chassis
x4
Networked
Chassis
CD-8DLCA
5 6 23 32
CD-16DLCA
5 5 20 32
Table 4-20 CD-8DLCA/CD-16DLCA LED Indications
LED Indication
Operation Status Remarks
Live LED
(Green)
Busy LED
(Red)
On On System Initializing –
Flash (1s) On The assignment of the unit is refused.
When you exceed the system
capacity.
When the main software
version is not matched.
Flash (1s) Trouble found during self-diagnostics. –