EasyManua.ls Logo

NEC Univerge SV8100 - Installation; LED Indications

NEC Univerge SV8100
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 4.1
System Hardware Manual 4 - 55
4.3.2 Installation
Install the CD-4LCA
/ CD-8LCA blade into any available universal
slot.
. If the PZ-4LCA/PZ-8LCE is used, install this prior to inserting the CD-8LCA
into the chassis
4.3.3 LED Indications
LED indications for the CD-4LCA
/CD-8LCA are listed in Table 4-26
CD-4LCA/CD-8LCA LED Indications. Each LED is listed with its
associated function and LED and Operational status. Refer to
Figure 4-19 CD-4LCA Blade on page 4-52 and Figure 4-20 CD-8LCA
Blade on page 4-53 for the location of the LEDs on the blades.
When connecting a fax machine or analog
modem, make sure to set Program 15-03-03 to
1 (special terminal) to avoid communication
problems.
The SLIU and SLIDB are categorized as
TNV2. With this designation, off-premise
wiring is not acceptable. Any cabling to the
SLIU blade must be within the building – no
outside cabling is permitted.
Branch connection is not acceptable.
Table 4-26 CD-4LCA/CD-8LCA LED Indications
LED Indication
Operation Status Remarks
Live LED
(Green)
Busy LED
(Red)
On On System Initializing
Flash (1s) On The assignment of the unit is refused.
When you exceed the system
capacity.
When the main software
version is not matched.
Flash (1s) Trouble found during self-diagnostics.
Flash
(100ms)
On
Normal
Operation
A Channel is busy (use
another from CH1 ~ CHx).
Off All channels are idle.