UNIVERGE SV8100 Issue 4.1
System Hardware Manual 4 - 55
4.3.2 Installation
Install the CD-4LCA
/ CD-8LCA blade into any available universal
slot.
. If the PZ-4LCA/PZ-8LCE is used, install this prior to inserting the CD-8LCA
into the chassis
4.3.3 LED Indications
LED indications for the CD-4LCA
/CD-8LCA are listed in Table 4-26
CD-4LCA/CD-8LCA LED Indications. Each LED is listed with its
associated function and LED and Operational status. Refer to
Figure 4-19 CD-4LCA Blade on page 4-52 and Figure 4-20 CD-8LCA
Blade on page 4-53 for the location of the LEDs on the blades.
When connecting a fax machine or analog
modem, make sure to set Program 15-03-03 to
1 (special terminal) to avoid communication
problems.
The SLIU and SLIDB are categorized as
TNV2. With this designation, off-premise
wiring is not acceptable. Any cabling to the
SLIU blade must be within the building – no
outside cabling is permitted.
Branch connection is not acceptable.
Table 4-26 CD-4LCA/CD-8LCA LED Indications
LED Indication
Operation Status Remarks
Live LED
(Green)
Busy LED
(Red)
On On System Initializing –
Flash (1s) On The assignment of the unit is refused.
When you exceed the system
capacity.
When the main software
version is not matched.
Flash (1s) Trouble found during self-diagnostics. –
Flash
(100ms)
On
Normal
Operation
A Channel is busy (use
another from CH1 ~ CHx).
–
Off All channels are idle. –