Issue 4.1 UNIVERGE SV8100
4 - 50 Installing the SV8100 Blades
4.2.2 Installation
The PZ-8DLCB is installed on the CD-8DLCA. To install:
1. Connect the PZ-8DLCB to the CN2 connector on the
CD-8DLCA blade. Refer to Figure 4-16 CD-8DLCA Blade on
page 4-44 for the location of the connectors on the blade.
2. Install the CD-8DLCA into a slot.
3. Each CNx01 connector (CN101, CN201, CN301, CN401) is
used to connect up to four digital extensions.
4.2.3 PZ-8DLCB Daughter Board Cable Connection
The PZ-8DLCB blade has connections for CN301 and CN401 Refer
to Figure 4-17 CD-16DLCA Blade for connector locations.
The following tables show the cable connections of the two RJ-61
connectors on the PZ-8DLCB.
Table 4-23PZ-8DLCB CN301 Connection
RJ-61 Cable Connector
CN301 (ports 9~12)
Pin No. Connection
1 (T4) Tip for port 12
2 (T3) Tip for port 11
3 (T2) Tip for port 10
4 (R1) Ring for port 9
5 (T1) Tip for port 9
6 (R2) Ring for port 10
7 (R3) Ring for port 11
8 (R4) Ring for port 12