EasyManua.ls Logo

NEC Univerge SV8100 - Outside Line Types; Transmission, Network, and Control Specifications; Transmission

NEC Univerge SV8100
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 4.1
System Hardware Manual 2 - 21
Recommended Long Term Humidity: 10 ~ 90% RH
Blades -
CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTA,
PZ-4COTE, CD-PRTA
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature: -20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 20 ~ 90% RH
Door Box
Operating Temperature: -20
o
C ~ 60
o
C
Operating Humidity: 20 ~ 80% (non-condensing)
SV8100 Power Supply –
MPS7101
Operating Temperature: 0
o
C ~ +40
o
C
Recommended Long Term Temperature: -40
o
C ~ 75
o
C
Operating Humidity: 20 ~ 95% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 95% RH
5.4 Outside Line Types
The following outside lines can be used with the UNIVERGE SV8100 system.
4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)
Digital Trunk T1/FT1 (Loop Start, Tie Line (E&M), or DID Signaling)
ISDN-BRI Trunks
ISDN-PRI Trunks
VoIP Trunks (Internet Protocols)
5.5 Transmission, Network, and Control Specifications
5.5.1 Transmission
Data Length:
From Multiline Terminal to CD-8DLCA: 23 bits
From CD-8DLCA to Multiline Terminal: 23 bits
Data Transmission Rates:
Between CD-8DLCA and Multiline Terminal: 184K bps (voice and
signaling)
Scanning Time for each Multiline Terminal: 32 ms.