UNIVERGE SV8100 Issue 4.1
System Hardware Manual 2 - 21
Recommended Long Term Humidity: 10 ~ 90% RH
Blades -
CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTA,
PZ-4COTE, CD-PRTA
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature: -20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 20 ~ 90% RH
Door Box
Operating Temperature: -20
o
C ~ 60
o
C
Operating Humidity: 20 ~ 80% (non-condensing)
SV8100 Power Supply –
MPS7101
Operating Temperature: 0
o
C ~ +40
o
C
Recommended Long Term Temperature: -40
o
C ~ 75
o
C
Operating Humidity: 20 ~ 95% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 95% RH
5.4 Outside Line Types
The following outside lines can be used with the UNIVERGE SV8100 system.
4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)
Digital Trunk T1/FT1 (Loop Start, Tie Line (E&M), or DID Signaling)
ISDN-BRI Trunks
ISDN-PRI Trunks
VoIP Trunks (Internet Protocols)
5.5 Transmission, Network, and Control Specifications
5.5.1 Transmission
Data Length:
From Multiline Terminal to CD-8DLCA: 23 bits
From CD-8DLCA to Multiline Terminal: 23 bits
Data Transmission Rates:
Between CD-8DLCA and Multiline Terminal: 184K bps (voice and
signaling)
Scanning Time for each Multiline Terminal: 32 ms.