Issue 4.1 UNIVERGE SV8100
6 - 12 Installing SV8100 Optional Equipment
8. Remove the back half of the Door Box and attach this mounting bracket
to the wall with the two screws provided.
9. Connect the two-conductor station cable from the CN4 connectors within
the PGD(2)-U10 ADP to the Door Box terminals. These wires must be
routed through the opening in the bottom of the Door Box mounting
bracket.
. Be sure to maintain the proper polarity.
10. Replace the front half of the Door Box and reattach the screw to secure it
in place.
11. To connect a Door Box to an external relay for an unlock device, for
example, connect one-pair 24 AWG station cable from the Relay 5 (for
Door Box 1) or Relay 6 (for Door Box 2) connectors (CN5) in the
PGD(2)-U10 ADP. Connect the opposite end to the unlock device.
. Refer to External Page and Door Box/Page Relays on page 6-18 for additional
information when using the CD-CP00 relay.