UNIVERGE SV8100 Issue 4.1
System Hardware Manual 2 - 13
SECTION 4 POWER-BASED CALCULATOR CHART
The Univerge SV8100 system uses two types of power factors. For a single chassis
chart refer to Table 2-6 Board Power Factor. For the maximum number of specific
blades per package, see Table 2-7 Maximum Number of Package Installed. Refer to
Table 2-8 Terminal Power Factor below, for the Terminal/ Adapter power chart.
Table 2-6 Board Power Factor
Board Power Factor
Total =<7
Item Power Factor
CD-CP00 1
CD-RTB 2
CD-VM00 2
CD-ETIA 2
CD-PVAA 1
PZ-32IPLA 1
PZ-64IPLA 2
PZ-128IPLA 2
Table 2-7 Maximum Number of Package Installed
Board
(Power Factor)
Maximum Number of Package Installed
9.5 inch
19 inch
with CCPU
19 inch
without
CCPU
4 x 19 inch
CD-ETIA (2) 2 3 3 12
CD-PVAA (1) 2 5 6 23
CD-RTB (2) 1228