84 Chapter 4 Use the PLC applications to control your workflow
Define the original release mode
Define the original release mode
Introduction
Use the original release mode setting to define if the scanner must hold or release the
original after the scan procedure.
Before you begin
Open the Océ Settings Editor and log on as Key Operator. Take the following steps
to log on.
1. Click 'File' and select 'Log on'.
2. Select 'Key Operator' and enter the password.
How to define the original release mode
1. Click 'View' and select 'Key Operator settings'.
2. Navigate to Key Operator - Scanner - Original release mode.
3. Select the required value.
You can select one of the following modes.
Hold the original at the front.
Release the original at the front.
Hold the original at the back.
Release the original at the back.
4. Click 'Apply' to confirm the settings.
5. Click 'File' and select 'Log off' to prevent unauthorized use.
Note: You can also define the original release mode at the scanner operator panel.
Select 'System' - 'Original release mode' - 'Release' / 'Hold' and 'Rewind''Yes' /'No'.
Result
The original release mode is defined.