App-36
Appendix-1 Parameter List
Appendix
Input terminal response
C160
Input terminal
response time 1
[Input [1] resp.time]
0 to 200 (× 2 ms) 1
No ms 4-108
C161
Input terminal
response time 2
[Input [2] resp.time]
0 to 200 (× 2 ms) 1
C162
Input terminal
response time 3
[Input [3] resp.time]
0 to 200 (× 2 ms) 1
C163
Input terminal
response time 4
[Input [4] resp.time]
0 to 200 (× 2 ms) 1
C164
Input terminal
response time 5
[Input [5] resp.time]
0 to 200 (× 2 ms) 1
C165
Input terminal
response time 6
[Input [6] resp.time]
0 to 200 (× 2 ms) 1
C166
Input terminal
response time 7
[Input [7] resp.time]
0 to 200 (× 2 ms) 1
C167
Input terminal
response time 8
[Input [8] resp.time]
0 to 200 (× 2 ms) 1
C168
FW terminal response
time
[Input [FW] resp.time]
0 to 200 (× 2 ms) 1
Others
C169
Multi-step speed/
position
determination time
[Multi-spd
determ.time]
0 to 200 (× 10 ms) 0 No ms
4-16
4-137
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page