A-145
Appendices
CJ2 CPU Unit Software User’s Manual
A-3 Auxiliary Area
App
A-3-1 Read-only Area (Set by System)
A472 --- EM Bank B Des-
ignation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A473 --- EM Bank C Des-
ignation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A474 --- EM Bank D Des-
ignation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A475 --- EM Bank E Des-
ignation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A476 --- EM Bank F Des-
ignation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A477 --- EM Bank 10
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A478 --- EM Bank 11
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A479 --- EM Bank 12
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A480 --- EM Bank 13
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A481 --- EM Bank 14
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A482 --- EM Bank 15
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A483 --- EM Bank 16
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
A484 --- EM Bank 17
Designation
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Fixed value
is set.
Fixed
value is
set.
---
Address
Name Function
Status
after mode
change
Status at
startup
Write timing/
Related flags, set-
tings
Words Bits