12. Supplementary Explanation of Communication Function
12-1. About communication protocol
VF100 conforms to two protocols that are "MEWTOCOL-COM" and "MOD-BUS (RTU)".
In any event, 1: N communication is always applied.
"MEWTOCOL-COM"
Communication protocol used for programmable logic controller (PLC) in our company.
"MOD-BUS (RTU)"
Communication protocol applicable to programmable logic controller (PLC) developed
by the U. S.
12-2. General remarks on MEWTOCOL-COM in inverter
Host computer transmits command (order) to the inverter, and receives response (answer)
from the inverter.
According to this step, by means of session between host computer and inverter, the host
computer can receive or transmit various messages.
Text
Command message
Response message (normal)
ASCII code transmission.
Original transmission right belongs to the host computer.
Each time a command message is transmitted, the transmission right will be transferred.
Host
computer
Inverter
Code
inspection
Header
Transmission
destination
Terminator
Text
Code
inspection
Header
Transmission
destination
Terminator