(1) It does not support multiple frames, but only support single frame.
The inverter conforms to MEWTOCOL-COM, however, note that there are some differences as below.
(2) The usable commands are the following 11 types:
(3) The data code when using WD and RD commands is "D" (data register)
12-3. Precautions on MEWTOCOL-COM in inverter
(4) The constant code when using WCS, WCP, RCS and RCP commands is "R" (internal relay)
(5) A maximum of 40 contacts can be registered for the MC command.
(6) Header supports "%" only.
RCS, RCP, WCS, WCP, RCC, WCC, RD, WD, MC, MD, MG
(7) There is no distinction between data and setting areas in the internal memory of the inverter.
It can be treated as word data (16 bits) and contact data (1 bit) for the same address (region).
12-3.1 About message format
[Basic format (single frame)]
Command
message
Response
message (normal)
Response
message (abnormal)
%
Transmission
destination
H L
#
Command
code
Text data
BCC
H L
cr
%
Transmission
source
H L
Response
code
Text data
BCC
H L
cr
%
Transmission
source
H L
Error code
BCC
H L
cr
H L
Horizontal parity range
Text