Function parameters in the above table will be described in detail as bellow. Depending
on the load in use and operation state of the motor to set these parameters.
P0011
st
acceleration time
Used to set the time to accelerate to the maximum output frequency from 0.5Hz.
Max. output
frequency
The display code for 0.04s is "000".
The maximum output frequency is set with parameters
P005 and P008.
Output
frequency(Hz)
0.5
Acceleration
time
0.1(0.1999.9), 1(10003600)
Setting unit (s)
0.040.13600
Data setting range (s)
P0021
st
deceleration time
Used to set the time to decelerate to the maximum output frequency from 0.5Hz.
The display code for 0.04s is "000".
The maximum output frequency is set with parameters
P005 and P008.
0.1(0.1999.9), 1(10003600)
Setting unit (s)
0.040.13600
Data setting range (s)
Output
frequency
(Hz)
Max. output frequency
0.5
Deceleration
time
Note
Take note that if acceleration time is set to a too short value, overcurrent may flow
due to different load states.
Note
Take note that if deceleration time is set to a too short value, overcurrent may flow
due to different load states.
62
9-3 Functional Descriptions (By Parameters)
P005, P008
Related
parameters
P005, P008
Related
parameters