12-4. MEWTOCOL-COM command in inverter
The usable commands are the following 11 types.
・ The data code when using WD and RD commands is "D" (data register).
・ The contact code when using WCS, WCP, WCC, RCS, RCP, and RCC commands is
"R". (internal relay)
・ A maximum of 40 contacts can be registered for the MC command.
Performance of MonitorMG
Registration of Monitor Data and Canceling of RegistrationMD
Registration of Monitor Contact and Canceling of Registration
MC
Write Data AreaWD
Read Data AreaRD
Write Contact Message in Word UnitWC
C
Write Multiple Contacts MessageWCP
Write Contact Message in 1 Contact UnitWCS
Read Contact Message in Word UnitRCC
Read Multiple Contacts MessageRCP
Read Contact Message in 1 Contact UnitRCS
DetailsCode command
・ A maximum of 16 data can be registered for the MD command.
158