n012:Operation control status monitor
Indicates the operation control status of the inverter. Each LED segment lights and
lights out according to the details of lighting and lighting out shown in the following table.
Normally, segment data i ~ I light.
g lights outg lightsSW5 command status
h lights outh lights
In operation of timer
LED segment indication
Command status
Monitor
No.
a1 lights outa1 lights
In operation of pulse input
f lights outf lightsSW4 command status
e lights oute lightsSW3 command status
d lights outd lightsSW2 command status
c lights outc lightsSW1 command status
b lights outb lights
Reverse run command status
a lights outa lights
Run command status
n012
0: without command1: with command
When command status is "in operation of timer" and parameter P45 (multi speed
function setting) is set to "3" or "4", it lights if run command is input.
When command status is "in operation of pulse input" and parameter P45 (multi speed
function setting) is set to "5" or "6", it lights if run command is input.