Safety 1-3
AC30 series Variable Speed Inverter
WARNING! - Ignoring the following may result in injury or damage to equipment
SAFETY
Where there is conflict between EMC and Safety requirements, personnel safety shall always take precedence.
Never perform high voltage resistance checks on the
wiring without first disconnecting the inverter from the
circuit being tested.
Whilst ensuring ventilation is sufficient, provide guarding
and /or additional safety systems to prevent injury or
damage to equipment.
When replacing an inverter in an application and before
returning to use, it is essential that all user defined
parameters for the product’s operation are correctly
installed.
All control and signal terminals are SELV, i.e. protected by double
insulation. Ensure all external wiring is rated for the highest system
voltage.
Thermal sensors contained within the motor must have at least
basic insulation.
All exposed metalwork in the Inverter is protected by basic
insulation and bonded to a safety earth.
RCDs are not recommended for use with this product but, where
their use is mandatory, only Type B RCDs should be used.
EMC
In a domestic environment this product may cause radio
interference in which case supplementary mitigation
measures may be required.
This equipment contains electrostatic discharge (ESD)
sensitive parts. Observe static control precautions when
handling, installing and servicing this product.
This is a product of the restricted sales distribution class according
to IEC 61800-3. It is designated as “professional equipment” as
defined in EN61000-3-2. Permission of the supply authority shall be
obtained before connection to the low voltage supply.
WARNING! Control Unit Removal / Fitting
Isolate supply before plugging or unplugging control unit to the power stack.

Table of Contents

Other manuals for Parker AC30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 and is the answer not in the manual?

Parker AC30 Specifications

General IconGeneral
Protection RatingIP20
SeriesAC30
TypeVariable Frequency Drive
Overload Capacity150% for 60 seconds
Cooling MethodFan Cooled
Communication ProtocolsCANopen
Power Range0.75 to 250 kW (1 to 350 hp)
Switching Frequency2kHz to 16kHz
SafetySafe Torque Off (STO)
Output CurrentModel Dependent
Power Rating0.75 to 250 kW (1 to 350 hp)
Efficiency>97%
Protection FeaturesOvercurrent, overvoltage, undervoltage, short circuit, overheating
DimensionsModel Dependent
WeightModel Dependent
Operating Temperature-10°C to +40°C
Output Voltage0 to Input Voltage

Related product manuals