Setup Wizard 9-8 
AC30 series Variable Speed Inverter 
On-board Ethernet 
Configuration of the on board Ethernet option. 
Select TRUE to configure the on board Ethernet port. Select FALSE to skip this section 
Only visible if DHCP and Auto IP are both FALSE. 
Only visible if DHCP and Auto IP are both FALSE. 
Only visible if DHCP and Auto IP are both FALSE. 
Select TRUE to configure the on board Ethernet port to also act as a Modbus IP client. Select FALSE to skip the 
following parameters 
Sets the maximum number of Modbus clients allowed.  If set to zero, then no connections will be allowed. 
Set TRUE to enable the Modbus Trip.  The parameter Modbus Timeout must be set to a value other than zero 
If set to TRUE, the most significant word of a 32-bit parameter will be mapped to the first register, and the least 
significant word to the next register. 
Sets the process active timeout 
Autotune Parameters 
Autotune enable and autotune mode. To run the autotune process, complete the wizard then run the inverter. 
Select TRUE to enable a motor autotune next time the motor is started. (Only visible for induction motor 
sensorless and feedback vector control mode). Refer to Appendix D Parameter Reference, section D6, for more 
details. 
 
Finalising Setup 
Once the Setup Wizard has been run to completion the feature is automatically disabled. Re-starting the inverter will not cause the Setup Wizard 
to be run again. (If it is desired to re-run the Setup Wizard, this can be achieved as detailed above in “Starting the Setup Wizard”).