EasyManua.ls Logo

Parker AC30 - Page 249

Parker AC30
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Compliance C-36
AC30 series Variable Speed Inverter
Supply Harmonic Analysis (Frame K - Normal Duty)
Assumptions: Rsce ≥ 120 at 400V where Q
1n
is the rated rms value of the fundamental voltage of the supply
transformer. The results conform to IEC61000-3-12:2011.
Fundamental Voltage (V)
400
Drive Type
Three Phase
Motor Power
(kW)
160
200
250
160
200
250
Typical Motor
Efficiency %
93
93
93
93
93
93
Harmonic No.
RMS Current (A)
Harmonic No.
RMS Current (A)
1
255
318
397
25
7.0
9.0
11.6
3
0
0
0
27
0
0
0
5
76.7
88.5
103
29
6.3
8.0
10.1
7
39.0
44.9
53.0
31
5.3
6.8
8.7
9
0
0
0
33
0
0
0
11
21.9
27.4
34.4
35
4.7
6.0
7.6
13
14.9
19.1
24.5
37
4.1
5.3
6.7
15
0
0
0
39
0
0
0
17
12.8
16.2
20.5
40
0
0
0
19
9.6
12.5
16.1
Total RMS
Current (A)
278
342
418
21
0
0
0
23
8.7
11.0
14.0
* THD (I) %
36.5
34.1
32.3
* (Total Harmonic Distortion)
THD(V) x 100
Q
Q
h
2
1
n
h
40
h
2
%

Table of Contents