D-10 Parameter Reference
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Drive enabled to do AFE.
AFE PF Angle Demand
1692
Parameters::Regen Control::AFE
0.00
-90.00 to 90.00
deg
ALWAYS
Power factor angle demand.
AFE Phase Loss
1715
Parameters::Regen Control::AFE
NEVER
Indicates if phase loss occurred.
AFE Brake Mode
1716
Parameters::Regen Control::AFE
FALSE
ALWAYS
Sets AFE control into brake mode.
AFE Status
1721
Same as PNO 1703
0:INACTIVE
1:SYNCHRONIZING
2:SYCHRONIZED
3:SUPPLY FREQ HIGH
4:SUPPLY FREQ LOW
5:SYNC FAILED
NEVER
AFE module status reporting.