EasyManua.ls Logo

Parker AC30 - Page 463

Parker AC30
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Reference D-203
AC30 series Variable Speed Drive
PNO
Name
Path
Type
Default
Range
Units
WQ
View
Notes
MBus
2:500 KBPS
3:AUTO
0221
DeviceNet Actual Baud
Same as PNO 218
USINT
(enum)
Same as PNO 220
NEVER
OPERATOR
00969
0222
DNet Producing Inst
Same as PNO 219
WORD
0064
CONFIG
TECHNICIAN
00971
0223
DNet Consuming Inst
Same as PNO 219
WORD
0096
CONFIG
TECHNICIAN
00973
0224
EtherCAT State
Monitor::Communications::Option
Parameters::Option Comms::EtherCAT
USINT
(enum)
0:SETUP
1:NW INIT
2:INIT OR PREOP
3:SAFE OPERATIONAL
4:OPERATIONAL
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
NEVER
OPERATOR
00975
0225
EtherNet IP State
Monitor::Communications::Option
Parameters::Option Comms::EtherNet IP
USINT
(enum)
Same as PNO 214
NEVER
OPERATOR
00977
0226
ENet Producing Inst
Setup::Communications::Option
Parameters::Option Comms::EtherNet IP
WORD
0064
CONFIG
TECHNICIAN
00979
0227
ENet Consuming Inst
Same as PNO 226
WORD
0096
CONFIG
TECHNICIAN
00981
0228
Modbus RTU State
Monitor::Communications::Option
Parameters::Option Comms::Modbus RTU
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
00983
0229
Modbus Device Address
Setup::Communications::Option
Parameters::Option Comms::Modbus RTU
USINT
1
1 to 247
CONFIG
TECHNICIAN
7
00985
0230
Modbus RTU Baud Rate
Same as PNO 229
USINT
(enum)
4
0:1200 BPS
1:2400 BPS
2:4800 BPS
3:9600 BPS
4:19200 BPS
5:38400 BPS
6:57600 BPS
7:76800 BPS
8:115200 BPS
CONFIG
TECHNICIAN
00987
0231
Parity And Stop Bits
Same as PNO 229
USINT
(enum)
0
0:EVEN, 1 STOP
1:ODD, 1 STOP
2:NONE, 2 STOP
3:NONE, 1 STOP
CONFIG
TECHNICIAN
00989
0232
High Word First RTU
Same as PNO 229
BOOL
FALSE
CONFIG
TECHNICIAN
00991
0233
Modbus RTU Timeout
Same as PNO 229
TIME
3.000
0.000 to 65.000
s
CONFIG
TECHNICIAN
00993
0234
Modbus TCP State
Monitor::Communications::Option
Parameters::Option Comms::Modbus TCP
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
00995
0235
High Word First TCP
Setup::Communications::Option
Parameters::Option Comms::Modbus TCP
BOOL
FALSE
CONFIG
TECHNICIAN
00997
0236
Modbus TCP Timeout
Same as PNO 235
TIME
3.000
0.000 to 65.000
s
CONFIG
TECHNICIAN
00999
0237
Profibus State
Monitor::Communications::Option
Parameters::Option Comms::Profibus
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
01001
0238
Profibus Node Address
Setup::Communications::Option
Parameters::Option Comms::Profibus
USINT
0
0 to 126
CONFIG
TECHNICIAN
7
01003
0239
PROFINET State
Monitor::Communications::Option
Parameters::Option Comms::PROFINET IO
USINT
(enum)
0:SETUP
1:NW INIT
2:WAITING TO CONNECT
3:STOP MODE
4:CONNECTED
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
NEVER
OPERATOR
01005
0240
PROFINET Device Name
Same as PNO 239
STRING[32]
NEVER
OPERATOR
01007
0249
Braking Enable
Parameters::Motor Control::Braking
BOOL
TRUE
ALWAYS
TECHNICIAN
6
01025
0251
Brake Resistance
Parameters::Motor Control::Braking
REAL
100.00
0.01 to 1000.00
Ohm
STOPPED
TECHNICIAN
6
01029
0252
Brake Rated Power
Parameters::Motor Control::Braking
REAL
0.10
0.10 to 510.00
kW
STOPPED
TECHNICIAN
6
01031
0253
Brake Overrating
Parameters::Motor Control::Braking
REAL
25.00
1.00 to 40.00
STOPPED
ENGINEER
6
01033
0254
Braking Active
Parameters::Motor Control::Braking
BOOL
NEVER
TECHNICIAN
01035
0255
Autotune Enable
Setup::Motor Control::Autotune
Parameters::Motor Control::Autotune
BOOL
FALSE
STOPPED
TECHNICIAN
2
01037
0256
Autotune Mode
Same as PNO 255
USINT
(enum)
1
0:STATIONARY
1:ROTATING
STOPPED
TECHNICIAN
6
01039

Table of Contents