D-212 Parameter Reference
AC30 series Variable Speed Drive
PNO
Name
Path
Type
Default
Range
Units
WQ
View
Notes
MBus
0765
Active 1 - 32.02 UNDER VOLTAGE
Same as PNO 763
BOOL
NEVER
OPERATOR
02057
0766
Active 1 - 32.03 OVER CURRENT
Same as PNO 763
BOOL
NEVER
OPERATOR
02059
0767
Active 1 - 32.04 STACK FAULT
Same as PNO 763
BOOL
NEVER
OPERATOR
02061
0768
Active 1 - 32.05 STACK OVER CURRENT
Same as PNO 763
BOOL
NEVER
OPERATOR
02063
0769
Active 1 - 32.06 CURRENT LIMIT
Same as PNO 763
BOOL
NEVER
OPERATOR
02065
0770
Active 1 - 32.07 MOTOR STALL
Same as PNO 763
BOOL
NEVER
OPERATOR
02067
0771
Active 1 - 32.08 INVERSE TIME
Same as PNO 763
BOOL
NEVER
OPERATOR
02069
0772
Active 1 - 32.09 MOTOR I2T
Same as PNO 763
BOOL
NEVER
OPERATOR
02071
0773
Active 1 - 32.10 LOW SPEED I
Same as PNO 763
BOOL
NEVER
OPERATOR
02073
0774
Active 1 - 32.11 HEATSINK OVERTEMP
Same as PNO 763
BOOL
NEVER
OPERATOR
02075
0775
Active 1 - 32.12 INTERNAL OVERTEMP
Same as PNO 763
BOOL
NEVER
OPERATOR
02077
0776
Active 1 - 32.13 MOTOR OVERTEMP
Same as PNO 763
BOOL
NEVER
OPERATOR
02079
0777
Active 1 - 32.14 EXTERNAL TRIP
Same as PNO 763
BOOL
NEVER
OPERATOR
02081
0778
Active 1 - 32.15 BRAKE SHORT CCT
Same as PNO 763
BOOL
NEVER
OPERATOR
02083
0779
Active 1 - 32.16 BRAKE RESISTOR
Same as PNO 763
BOOL
NEVER
OPERATOR
02085
0780
Active 1 - 32.17 BRAKE SWITCH
Same as PNO 763
BOOL
NEVER
OPERATOR
02087
0781
Active 1 - 32.18 LOCAL CONTROL
Same as PNO 763
BOOL
NEVER
OPERATOR
02089
0782
Active 1 - 32.19 COMMS BREAK
Same as PNO 763
BOOL
NEVER
OPERATOR
02091
0783
Active 1 - 32.20 LINE CONTACTOR
Same as PNO 763
BOOL
NEVER
OPERATOR
02093
0784
Active 1 - 32.21 PHASE FAIL
Same as PNO 763
BOOL
NEVER
OPERATOR
02095
0785
Active 1 - 32.22 VDC RIPPLE
Same as PNO 763
BOOL
NEVER
OPERATOR
02097
0786
Active 1 - 32.23 BASE MODBUS BREAK
Same as PNO 763
BOOL
NEVER
OPERATOR
02099
0787
Active 1 - 32.24 24 V OVERLOAD
Same as PNO 763
BOOL
NEVER
OPERATOR
02101
0788
Active 1 - 32.25 PMAC SPEED ERROR
Same as PNO 763
BOOL
NEVER
OPERATOR
02103
0789
Active 1 - 32.26 OVERSPEED
Same as PNO 763
BOOL
NEVER
OPERATOR
02105
0790
Active 1 - 32.27 STO ACTIVE
Same as PNO 763
BOOL
NEVER
OPERATOR
02107
0791
Active 1 - 32.28 FEEDBACK MISSING
Same as PNO 763
BOOL
NEVER
OPERATOR
02109
0792
Active 1 - 32.29 INTERNAL FAN FAIL
Same as PNO 763
BOOL
NEVER
OPERATOR
02111
0793
Active 1 - 32.30 CURRENT SENSOR
Same as PNO 763
BOOL
NEVER
OPERATOR
02113
0794
Active 1 - 32.31 POWER LOSS STOP
Same as PNO 763
BOOL
NEVER
OPERATOR
02115
0796
AR Trip Mask 2
Setup::Motor Control::Auto Restart
Parameters::Motor Control::Auto Restart
DWORD
(bitfield)
FFFFFFFF
0:33 A1
1:34 A2
2:35 A3
3:36 A4
4:37 A5
5:38 A6
6:39 A7
7:40 A8
ALWAYS
TECHNICIAN
02119
0797
AR Trip Mask 2.33 A1
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02121
0798
AR Trip Mask 2.34 A2
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02123
0799
AR Trip Mask 2.35 A3
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02125
0800
AR Trip Mask 2.36 A4
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02127
0801
AR Trip Mask 2.37 A5
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02129
0802
AR Trip Mask 2.38 A6
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02131
0803
AR Trip Mask 2.39 A7
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02133
0804
AR Trip Mask 2.40 A8
Same as PNO 796
BOOL
TRUE
ALWAYS
TECHNICIAN
02135
0829
Warnings 1 - 32
Monitor::Trips
Parameters::Trips::Trips Status
DWORD
(bitfield)
0:01 OVER VOLTAGE
1:02 UNDER VOLTAGE
2:03 OVER CURRENT
3:04 STACK FAULT
4:05 STACK OVER CURRENT
5:06 CURRENT LIMIT
6:07 MOTOR STALL
7:08 INVERSE TIME
8:09 MOTOR I2T
9:10 LOW SPEED I
10:11 HEATSINK OVERTEMP
11:12 INTERNAL OVERTEMP
12:13 MOTOR OVERTEMP
13:14 EXTERNAL TRIP
14:15 BRAKE SHORT CCT
15:16 BRAKE RESISTOR
16:17 BRAKE SWITCH
17:18 LOCAL CONTROL
18:19 COMMS BREAK
19:20 LINE CONTACTOR