EasyManua.ls Logo

Parker AC30 - Page 475

Parker AC30
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Reference D-215
AC30 series Variable Speed Drive
PNO
Name
Path
Type
Default
Range
Units
WQ
View
Notes
MBus
0961
Drive Name
Setup::Environment
Parameters::Device Manager::Drive info
STRING[23]
ALWAYS
TECHNICIAN
7
02449
0968
Warranty Trips
Parameters::Trips::Trips History
ARRAY[0..2]
NEVER
ENGINEER
02463
0969
Warranty Trips[0]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
ENGINEER
1
02465
0970
Warranty Trips[1]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
ENGINEER
1
02467
0971
Warranty Trips[2]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
ENGINEER
1
02469
0972
Warranty Trip Time
Parameters::Trips::Trips History
ARRAY[0..2]
NEVER
ENGINEER
02471
0973
Warranty Trip Time[0]
Parameters::Trips::Trips History
UDINT
0 to Max
s
NEVER
ENGINEER
1
02473
0974
Warranty Trip Time[1]
Parameters::Trips::Trips History
UDINT
0 to Max
s
NEVER
ENGINEER
1
02475
0975
Warranty Trip Time[2]
Parameters::Trips::Trips History
UDINT
0 to Max
s
NEVER
ENGINEER
1
02477
0977
Control Module Serial
Parameters::Device Manager::Drive info
STRING[15]
NEVER
OPERATOR
02481
0982
Startup Page
Setup::Environment
Parameters::Keypad::Graphical Keypad
USINT
(enum)
0
0:DEFAULT
1:CONTROL SCREEN
2:FAVOURITES
3:MONITOR
ALWAYS
TECHNICIAN
02491
0983
Display Timeout
Same as PNO 982
TIME
0.000
0.000 to 86400.000
s
ALWAYS
TECHNICIAN
02493
0987
Power Stack Required
Parameters::Device Manager::Drive info
USINT
(enum)
0
Same as PNO 543
CONFIG
ENGINEER
6
02501
0988
Target State
Parameters::Device Manager::Device State
USINT
(enum)
3
3:PREOPERATIONAL
7:OPERATIONAL
STOPPED
OPERATOR
2
02503
0989
Actual State
Parameters::Device Manager::Device State
USINT
(enum)
0:INITIALISING
1:INITIALISED
2:PREPARING PREOP
3:PREOPERATIONAL
4:PREPARING OP
5:FAILED TO READY
6:READY FOR OP
7:OPERATIONAL
8:FAULTED
9:FATAL ERROR RECOVER
NEVER
OPERATOR
02505
0990
Application FE State
Parameters::Device Manager::Device State
USINT
(enum)
Same as PNO 989
NEVER
OPERATOR
02507
0991
Base IO FE State
Parameters::Device Manager::Device State
USINT
(enum)
Same as PNO 989
NEVER
OPERATOR
02509
0992
Basic Drive FE State
Parameters::Device Manager::Device State
USINT
(enum)
Same as PNO 989
NEVER
OPERATOR
02511
0993
Ethernet FE State
Parameters::Device Manager::Device State
USINT
(enum)
Same as PNO 989
NEVER
OPERATOR
02513
0994
Keypad FE State
Parameters::Device Manager::Device State
USINT
(enum)
Same as PNO 989
NEVER
OPERATOR
02515
0995
Comms Option FE State
Parameters::Device Manager::Device State
USINT
(enum)
Same as PNO 989
NEVER
OPERATOR
02517
0996
IO Option FE State
Parameters::Device Manager::Device State
USINT
(enum)
Same as PNO 989
NEVER
OPERATOR
02519
0997
Config Fault Area
Parameters::Device Manager::Device State
USINT
(enum)
0:NONE
1:POWER STACK
2:OPTION IO
3:OPTION COMMS
4:APPLICATION
5:MOTOR CONTROL
6:KEYPAD
7:BASE COMMS
8:BASE IO
9:FEEDBACK MISSING
10:SYSTEM BOARD
NEVER
OPERATOR
02521
0998
RTA Code
Monitor::Trips
Parameters::Device Manager::Device State
UINT
0 to 65535
NEVER
OPERATOR
02523
0999
RTA Data
Same as PNO 998
DWORD
NEVER
OPERATOR
02525
1001
Save All Parameters
Parameters::Device Manager::Device Commands
BOOL
FALSE
ALWAYS
OPERATOR
2
02529
1002
Update Firmware
Parameters::Device Manager::Device Commands
BOOL
FALSE
STOPPED
ENGINEER
2
02531
1003
RTA Thread Priority
Parameters::Device Manager::Device State
SINT
-128 to 127
NEVER
OPERATOR
02533
1004
Thermistor Trip Level
Parameters::Option IO::Thermistor
REAL
1000
0 to 4500
Ohm
ALWAYS
TECHNICIAN
02535
1005
Language
Parameters::Device Manager::Setup Wizard
USINT
(enum)
0
0:ENGLISH
1:FRANCAIS
2:DEUTSCH
ALWAYS
TECHNICIAN
02537