F-5 Technical Specifications
AC30 series Variable Speed Drive
Power Supply = 380-480V ±10%, 50/60Hz 5%
Motor power, output current and input current must not be exceeded under steady state operating conditions.
Minimum repetitive power up / power down cycle time = 10 mins
Product Code
Motor Power
Output Current
(A)
Input Current
(A)
Estimated
Efficiency
Switching Frequency
(kHz)
nominal / maximum
Output Current Derate %/kHz
(applied above nominal switching
frequency)
FRAME E: Input currents for kW ratings are at 400V 50Hz ac input and for Hp ratings at 460V 60Hz ac input. Prospective short circuit current 5kA.
Normal Duty (Output Overload Motoring 110% for 60s)
31x-4E0016…
7.5kW
16
14.5
97%
4 / 16
5.5%
10Hp
14
12.1
31x-4E0023…
11kW
23
20.4
97%
4 / 16
5.1%
15Hp
21
18.0
Heavy Duty (Output Overload Motoring 150% for 60s, 180% for 3s short term rating)
31x-4E0016
5.5kW
12
10.7
97%
4 / 16
4.9%
7.5Hp
11
9.5
31x-4E0023
7.5kW
16
14.5
97%
4 / 16
4.9%
10Hp
14
12.7
FRAME F : Input currents for kW ratings are at 400V 50Hz ac input and for Hp ratings at 460V 60Hz ac input. Prospective short circuit current 5kA.
Normal Duty (Output Overload Motoring 110% for 60s)
31x-4F0032…
15kW
32
28.5
97%
4 / 12
6.3%
20Hp
27
24.5
31x-4F0038…
18.5kW
38
33.5
97%
4 / 12
6.7%
25Hp
36
30.2
Heavy Duty (Output Overload Motoring 150% for 60s, 180% for 3s short term rating)
31x-4F0032
11kW
23
21.7
97%
4 / 12
6.0%
15Hp
21
19.1
31x-4F0038
15kW
32
28.5
97%
4 / 12
6.1%
20Hp
27
24.5