3.1.1 Hazard analysis
The machine manufacturer must produce a hazard analysis for the machine. He must take
appropriate measures to ensure that unexpected movements do not lead to hazardous situ-
ations for either people or equipment.
3.1.2 Electrical data
Please note the electrical requirements stated in the chapters entitled "Technical Details",
"Wiring" and "Function Description".
INFORMATION
A 3L line choke with u
k
= 2% must be used in the event of a mains voltage
imbalance of > 3%. Install the line choke on the mounting plate in a way that
is EMC-compliant.
3.1.3 Ambient conditions
Please note the following conditions for using the servo amplifier:
} Operation of the servo amplifier is forbidden in the following conditions:
Potentially explosive areas
Environments containing corrosive and/or conductive acids, alkaline solutions, oils,
fumes or dusts
Where there is a direct connection to unearthed or asymmetrically earthed mains
supplies with U
N
>240V. See chapter entitled "Wiring", under "Mains voltage".
On ships and offshore installations
} The servo amplifier may only be operated in an enclosed control cabinet in compliance
with the ambient conditions defined under “Technical details”. Ventilation or cooling
may be required to maintain the control cabinet temperature below 40°C.
WARNING!
In a residential environment this product may cause high-frequency noise,
so that suppression measures may be required.
3.1.4 Guidelines for UL approval
The devices are certified to UL 508C and UL 840.
} UL 508C describes the fulfilment by design of minimum requirements for electrically op-
erated power converters, such as frequency converters and servo amplifiers.
} UL 840 describes the fulfilment by design of clearance and creepage distances on elec-
trical equipment and printed circuit boards.