Chapter B - CONTROL PANEL FUNCTIONS
B-2 Planmeca Compact i
NORMAL USER FUNCTIONS
Technical Manual
2 NORMAL USER FUNCTIONS
The control panel is always in the normal operating mode when the unit is switched on.
Please refer to the Planmeca Compact i User’s Manual for descriptions for the normal control
panel operation and instructions for normal everyday use of the unit.
3 USER PROGRAMMING MODE
There are several adjustments the user can perform to fulfil individual needs by using the user
programming mode.
All user programming follows the same pattern:
a) Press the program key to activate the programming mode. The indicator light will come on.
b) Select the desired function from the control panel.
c) Change the setting of the function with the foot control. Push the pedal halfway right to
increase the parameter value and halfway left to decrease it. If the pedal is pushed more than
0.4 sec., the value will change as long as the pedal is pushed.
d) Press the program key to store the new setting into the memory. The indicator light will go out.
e) When programming instrument settings; remove the instrument that you wish to program
from its holder. After identifying the instrument it can be either held out from or returned to its
holder. If returned you have 3 seconds time to enter the programming mode.
NOTE The maximum air and water flow rate of the syringe can not be changed via the
keyboard controls. However, there are screwdriver-adjustable valves inside the
console that can be adjusted if desired. Please refer to 3.2 “Adjusting syringe
water and air flow rates” on page F-27.
FUNCTION KEY SEQUENCE
FOR DETAILS
REFER TO
Programming
chair automatic
positions
4.1 “Automatic chair
positions” on page
B-4
Adjusting spray
water and air flow
on selected instru-
ment
4.2 “Instrument
spray flow rates” on
page B-4
Adjusting chip
blow air and water
flow on selected
instrument
4.3 “Chip blow flow
rates” on page B-5
A
D
C
B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planmeca Compact I and is the answer not in the manual?

Planmeca Compact I Specifications

General IconGeneral
SpittoonYes
Operating LightLED
Imaging TechnologyDigital
X-ray Tube Voltage60-70 kV
X-ray Tube Current7 mA
Focal Spot Size0.8 mm
Exposure Time Range3.2 s
Power Supply50/60 Hz

Related product manuals